DEPARTMENT OF CONDENSED MATTER PHYSICS
|
Real Crystal Physics
|
Equipment and Parameters
|
1. Deformation Machine ДУ-22 (France)
|
|
Maximum force Fmax = 5000 N
Minimum velocity of traverse displacement
V = 0.22 მკმ/წმ
|
2. Acoustic Spectrometer 1 (device for measuring internal friction and elastic modulus)
|
The range of measuring the internal friction
The frequency range of measuring
The temperature range
|
Q-1 = 10-6 - 10-1
ν = 0,2 – 60 kHz
T = 80 - 400 K
|
3. Spectrometers
|
- СФ-2 (Russia)
The measurement interval
Accuracy
|
186 - 1100 nm
1 %
|
- Specord 75 IR ("Karl Zeiss" , Germany)
The measurement interval (in the range of wave number)
Resolution
at 3200 cm-1
at 2500 cm-1 and lower
Accuracy
|
4000 - 400 cm-1
2 cm-1
1 cm-1
2 cm-1
|
- AvaSpec-2048-USB2-UA (The Netherlands), (fiber optics)
The measurement interval
Pixel
Diffraction latticeი
Diaphragm
Interface
|
UV/VIS/NIR
2048
UA (200 - 1100nm)
50
USB2
|
4. Optical (OSL) and high-temperature thermally stimulated luminescence (TSL) measuring device.
|
|
OSL Stimulation by blue LED light in the regime of constant intensity (continuous-wave)
TSL measurement interval: 300 - 775 K
Heating rate: 0.05 - 2 K/s
|
5. Differential calorimeter of a new generation (pulsed differential and pulsed scanning
differential calorimeters)
|
|
Temperature range of measurements: 1,7 – 400 K
Sensitivity: 10-8 – 10-9 W
Accuracy, δc/c: 10-4
Measured samples: solid, liquid
Operating regime: pulsed, continuous
|
6. Kolkhida – equipment for studying the interaction between polarized and oriented nuclei
and polarized neutrons.
Contains a spectrometer of polarized neutrons and 3He in 4He
solution cryostat with superconducting solenoid.
|
|
The temperature of a sample in cryostat T = 23 mK under the condition of 3He
circulation rate n = 1.10–3mol/s.
The maximum magnetic field in solenoid, H = 6 T.
The uniformity of field, ΔH/H < 10-4.
Polarization of neutrons Pn ~ 0.98 with respect to resolution energies ΔE/E < 10-2.
The fligt distanse from the moderator in the reactor radiation zone to the detector is
15.9 m and comprises the following distances:
moderator – polarizer: 12.4 m;
polarizer – analyzer: 2.5 m;
and analizer – detector: 1.0 m.
|
Spectrometer of polarized neutrons
|
1 – polarizer crystal; 2 – analyzer crystal; 3 – Soller collimator;
4 - guiding field electromagnets; 5 – flipper; 6 – shim; 7 – cryostat; 8 – detector.
|
Parameters of the polarized neutron beam
Brag glancing angle, Θ (deg)
|
19
|
12
|
6
|
4
|
3
|
Wave length, λ (Å)
|
1.15
|
0.74
|
0.37
|
0.25
|
0.19
|
Energy, Еn (eV)
|
0.062
|
0.15
|
0.60
|
1.3
|
2.3
|
Detector counting rate after the polarizer ,
n1 (s-1)
|
800
|
270
|
65
|
33
|
22
|
Polarized beam intensity, I1 (n/s cm2)
|
430
|
200
|
80
|
60
|
50
|
Detector counting rate after the analyzer, n2 (s-1)
|
70
|
23
|
3.1
|
0.6
|
0.2
|
|
7. Acoustic spectrometer 2.
|
|
The frequency range of measuring:
The temperature range:
The range of deformation amplitude:
The measurement error of internal friction in the intervals:
Q-1 ~ 10-3 - 10-5
Q-1 > 10-3
The measurement accuracy of elastic modulus:
The range of heating and cooling rate:
|
ν = 0,5 – 10 kHz
1,5 – 900 K
10-7 - 10-5
~ 2 %
~ 5 %
~ 0.01 %
1 - 10 K/min
|
8. Scanning differential calorimeter
|
The temperature range of measuring :
The heating rate:
Measurement sensitivity:
calorimeter
gravimeter
Accuracy of heat capacity measurement:
Medium:
|
150 - 1100 K
0.02 K/min – 30 K/min
15 mkW
1 mkg
1 - 3 %
vacuum or inert gas
|
9. Equipment for burning, hardening and hydrogenation of samples
|
The maximum temperature of working chamber:
Ultimate vacuum:
Volume:
Accuracy of pressure measurement:
|
10000 C
10-6 Torr
600 cm3
0.5 Torr
|
|
|